This series of products adopts power electronic conversion and intelligent control technology. It’s a high performance power supply designed for the ground power supply of aircraft air-borne equipment, and electronic and electrical equipment testing.
Product introduction
Product Parameter
Power Range |
1kVA |
2kVA |
3kVA |
5kVA |
6kVA |
10kVA |
15kVA |
20kVA |
25kVA |
30kVA |
|||||||
Input |
Phrase |
single Phase+PE |
three-phase three-wire+PE |
||||||||||||||
Voltage |
220V±10% |
380V±15% |
|||||||||||||||
Frequency(Hz) |
50Hz±5% |
||||||||||||||||
Output |
Voltage |
115V±20% |
|||||||||||||||
Voltage Resolution |
0.1V |
||||||||||||||||
Voltage Stability |
≤±1%FS |
||||||||||||||||
Frequency |
400Hz±20% |
||||||||||||||||
Frequency Resolution |
0.1Hz |
||||||||||||||||
Frequency Accuracy |
≤±0.01%FS |
||||||||||||||||
THD |
THD≤2%(Resistive Load Test ) |
||||||||||||||||
Overload Capacity |
125% 60min,I50% 10min,200% 1min protection. |
||||||||||||||||
Adaptable Load |
Typeless restrictions, suitable for motor and rectifier type loads. |
||||||||||||||||
Dynamic Characteristics |
overshoot<15%, dynamic response time<1mS, the recovery time meets the requirements of GJB181. |
||||||||||||||||
Protection |
Input over/under voltage, output over-voltage, overload, short circuit, cut-off current, phase loss, internal overheating. |
||||||||||||||||
Operating Display |
Display Mode |
LCD panel, touch-key operation. |
|||||||||||||||
Display Content |
Display voltage/current/frequency/Operating status/fault information/control mode (local /remote control). |
||||||||||||||||
Indication Resolution |
Voltage: ±1%FS; current: ±2%FS; frequency:±0.1%FS |
||||||||||||||||
Comprehensive Characteristics |
Impact Resistance |
The power grid has a strong ability to resist instantaneous fluctuations, and it can effectively simulate all kinds of interference from the power grid surge, sag, peak and so on. |
|||||||||||||||
Efficiency |
≥80% |
≥85% |
|||||||||||||||
Noise |
<55dB |
<60dB |
|||||||||||||||
Inlet and Outlet Ports |
Back Inlet and Outlet |
||||||||||||||||
Working Environment |
Temperature Grade |
1. -5℃~40℃; 2. -25℃~50℃; 3. -40℃~55℃ |
|||||||||||||||
Cooling Mode |
Forced fan cooling |
||||||||||||||||
Operating Humidity |
30%RH-90%RH (No condensation) |
||||||||||||||||
Storage Humidity |
10%RH-95%RH (No condensation) |
||||||||||||||||
Control Mode |
Local Control |
LCD , Touch-key operation |
|||||||||||||||
Remote Control |
RS-232、RS-485 or GPIB |
||||||||||||||||
Reliability
|
MTBF |
1.0×105h |
|||||||||||||||
MTTR |
0.5h |
||||||||||||||||
Safety |
Insulation Resistance |
Above 500Vdc、20MΩ |
|||||||||||||||
Withstand Voltage Insulation |
1800Vdc/5mA/1min |
||||||||||||||||
Dimension |
(W×H×D)mm |
(1) |
(2) |
(3) |
(4) |
(5) |
|||||||||||
Weight(KG) |
Referenced Value |
25 |
35 |
40 |
45 |
100 |
150 |
180 |
2. The power supply can be customized
Online booking