Product introduction
Product Parameter
Model Items |
WA90P-220S09C |
WA90P-220S12C |
WA90P- 220S15C |
WA90P-220S19C |
WA90P-220S24C |
WA90P-220S36C |
WA90P-220S48C |
|||||||||
Input |
Voltage Range(VAC) |
85-265 |
||||||||||||||
Frequency(Hz) |
47~63 |
|||||||||||||||
Current (MAX)(Arms) |
1.4 |
|||||||||||||||
Inrush Current(MAX)(A) |
70 |
|||||||||||||||
Power Factor(Typ) |
≥0.91 |
|||||||||||||||
Output |
voltage(V) |
9 |
12 |
15 |
19 |
24 |
36 |
48 |
||||||||
Current (A) |
10.00 |
7.50 |
6.00 |
4.73 |
3.75 |
2.50 |
1.87 |
|||||||||
Efficiency(Typ) |
88% |
89% |
89% |
89% |
90% |
90% |
90% |
|||||||||
Voltage Tolerance |
±5% |
±3% |
±3% |
±3% |
±3% |
±3% |
±3% |
|||||||||
Voltage Ripple & noise(mVp-p) |
120 |
120 |
120 |
150 |
150 |
150 |
150 |
|||||||||
Load regulation |
±5% |
±3% |
±3% |
±3% |
±3% |
±3% |
±3% |
|||||||||
Start-up time (mS) |
1000 |
|||||||||||||||
Protection |
Over Load |
Over rated power105-150% |
||||||||||||||
Hiccup mode protection,automatically resume work if overload comes to rated load. |
||||||||||||||||
Over Voltage |
9.4~10.2 |
12.6~16.2 |
15.7~20.3 |
18.9~24.3 |
25.2~32.4 |
37.8~48.6 |
50.4~64.8 |
|||||||||
Turn-off output, restart to restore normal. |
||||||||||||||||
Over Heat |
Turn-off output, after temperature recovery, restart to restore normal. |
|||||||||||||||
Working Environment |
Working Temp.(℃) |
-20~85 |
||||||||||||||
Storage Temperature(℃) |
-40~85 |
|||||||||||||||
Operating Humidity |
10~90%RH, No condensation |
|||||||||||||||
Others |
Test Voltage |
Input-output withstand 3KVAC, test time: 60s, Leakage current less than 5mA |
||||||||||||||
Insulation Resistance |
Input-output, insulation voltage 500VDC, Insulation resistance 100MΩ(25℃、Relative Humidity 95%) |
|||||||||||||||
Overall Dimension |
150x60x39mm |
|||||||||||||||
Weight |
0.45Kg |
|||||||||||||||
Remarks
|
1. Ripple and noise measurement: Use twisted pair wire, connect 0.1uF and 47uF capacitors at the terminal, and measure under the condition of 20MHz oscilloscope bandwidth; 2. Voltage Accuracy: including setting error and load regulation; 3. Standard configuration of structural size of plugs and wiring, it’s also can be customized. |
Structure & Size
1. Overall Dimensions
2. Standard Power Plug
Output Plug |
Joint definition |
|
Outside Inside |
Note:Above plug is the standard product interface. For special requirements, it also can be configured according to customer’s request. |
Online booking